ZSR Sensores de corriente montados en placa

Resultados: 8
Seleccionar Imagen N.° de pieza Fabricante: Descripción Hoja de datos Disponibilidad Precio: (USD) Filtre los resultados en la tabla por precio unitario en función de su cantidad. Cantidad RoHS Modelo ECAD Régimen de corriente Tipo de sensor Tiempo de respuesta Exactitud Banda de frecuencias Voltaje de alimentación operativo Tipo de salida
LEM Sensores de corriente montados en placa Current Transducer LZSR 100-TP. For the electronic measurement of current: DC, AC, pulsed, with galvanic separation between the primary and the secondary circuit. 57En existencias
Min.: 1
Mult.: 1

100 A Closed Loop 2 us 1.25 % 200 kHz 5 V Digital, Analog
LEM Sensores de corriente montados en placa Current Transducer LZSR 150-P/SP1. For the electronic measurement of current: DC, AC, pulsed, with galvanic separation between the prmary and the secondary circuit. 115En existencias
Min.: 1
Mult.: 1

150 A Closed Loop 3 us 1.4 % 200 kHz 5 V Digital, Analog
LEM Sensores de corriente montados en placa Current Transducer LZSR 150-TP. For the electronic measurement of current: DC, AC, pulsed, with galvanic separation between the prmary and the secondary circuit. 51En existencias
Min.: 1
Mult.: 1

150 A Closed Loop 2 us 1.25 % 200 kHz 5 V Digital, Analog
LEM Sensores de corriente montados en placa Current Transducer LZSR 100-P. For the electronic measurement of current: DC, AC, pulsed, with galvanic separation between the primary and the secondary circuit. 137En existencias
Min.: 1
Mult.: 1

100 A Closed Loop 3 us 1.4 % 200 kHz 5 V Digital, Analog
LEM Sensores de corriente montados en placa Current Transducer LZSR 150-P. For the electronic measurement of current: DC, AC, pulsed, with galvanic separation between the primary and the secondary circuit. 88En existencias
Min.: 1
Mult.: 1

150 A Closed Loop 3 us 1.4 % 200 kHz 5 V Digital, Analog
LEM Sensores de corriente montados en placa Current Transducer LZSR 80-P. For the electronic measurement of current: DC, AC, pulsed, with galvanic separation between the primary and the secondary circuit. 166En existencias
Min.: 1
Mult.: 1

80 A Closed Loop 3 us 1.4 % 200 kHz 5 V Digital, Analog
LEM Sensores de corriente montados en placa Current Transducer LZSR 200-P/SP1. For the electronic measurement of current: DC, AC, pulsed, with galvanic separation between the prmary and the secondary circuit. 112En existencias
Min.: 1
Mult.: 1

200 A Closed Loop 3 us 1.4 % 200 kHz 5 V Digital, Analog
LEM Sensores de corriente montados en placa Current Transducer LZSR 200-TP/SP1. For the electronic measurement of current: DC, AC, pulsed, with galvanic separation between the prmary and the secondary circuit. 27En existencias
Min.: 1
Mult.: 1

200 A Closed Loop 3 us 1.4 % 200 kHz 5 V Digital, Analog